Clariion plaids on RHEL 4
We will begin with a quick mention of the problem currently under investigation with EMC support:
- Host: Dell PowerEdge R710, PowerPath, RHEL 4.8.
- SAN: Clariion CX4-120
- Connectivity: iSCSI – two ports per SP, two ports on the host, two VLANs on Nortel ERS5520.
Problem: if we present two LUNs to the host, put them into a single VG, then create an LV with no striping (LUNs get concatenated on that volume), everything is good. If we take the same LUNs and put them into a striped LV per various EMC Best Practices documents (since the LUNs themselves are striped across physical disks EMC calls this layout “plaids”), read performance suffers in a very bad way, dropping to about 4MB/sec. Write performance stays perfect at over 100MB/sec.
Advertisement
Categories: Operating Systems, Storage
Tags: Clariion, performance, SAN
Comments (0)
Trackbacks (0)
Leave a comment
Trackback
Recent Posts
- Why you must not use Azure if you want to keep your sanity
- Cisco ASA Group Policy Access Lists Are Evil
- Linux, EMC SANs, and TCP Delayed ACKs
- VMware vCenter Server 5 Upgrade and Service Accounts
- Why pfSense is not production ready
- Fixing VM-based pfSense CARP announcement echoes when using teamed network adapters
- Missing access points after upgrade of Cisco Wireless LAN Controller to Release 5.2
- Solution of the Clariion plaid issue